Beam probe
Reads the nearby traced beam without intercepting it, showing a selected spectrum, wavelength, power, polarization, pulse duration, or intensity-over-time view.
Open in the canvas →In the real world
Laboratory beam diagnostics normally require a sensor or pickoff that interacts with the light. A non-intercepting label in a ray diagram instead communicates a property already known from the model; it is not a physical measuring instrument.
In OpticalSetup
Place the crosshair near a traced beam and select the property to show. Spectrum and time views provide range controls; pulse duration requires suitable pulsed light. With one beam in its sampling circle, the spectrum, wavelength, polarization, duration and time views describe the nearest traced beam. When several beams cross the circle, four views describe all of them: the spectrum sums their spectral densities, each weighted by its watts (when a source has no power setting, every beam is weighted by its share of its own source's power instead, and the card says relative); the wavelength view lists each colour; polarization shows one disc per beam, named by its wavelength; and the time view draws every train on one axis and says whether the pulses arrive together (within half a pulse duration — the duration at the probe where it is known, otherwise the source's, and the card then says so), which beam comes first and by how much, or that trains at different repetition rates have no fixed delay. Beams of one kind of light are told apart by the route they took: the sampling rays of one beam are one beam however a lens spreads their path lengths, while two arms of a split pulsed laser are two beams as soon as their pulses arrive apart — 200 fs of arm difference is read as 0.2 ps — so a delay line can be aligned by watching the delay go to zero. Arms that arrive together count as one beam, and so do arms a whole number of repetition periods apart (the round trips of a synchronously pumped cavity), which land on the same pulses — unless a chopper, AOM or other modulator gates the train, since the modulation does not repeat with the laser period and such arms stay apart. The circle is drawn dashed whenever it decides what is read. Average power is different: it adds up every beam that crosses the probe's sampling circle (10 mm across unless set otherwise, drawn dashed around the crosshair), each with the watts its own source contributes, exactly as a power meter adds up what reaches its face — so a probe and a meter on the same light read the same. Two beams that overlap, such as an OPA's seed and the gain it received, are read together; widen or narrow the circle to take in several beams or one. A beam is counted where it enters the circle, so light split or reflected inside the circle is not counted twice, and light emitted inside it is not counted.
The example puts a spectrum probe between a broadband source and a detector. Move it away from the beam, then back, to see its dependence on the selected location. It never absorbs light or creates a new optical branch.
This is a diagnostic annotation with direct access to traced properties. It does not represent a laboratory probe's calibration, noise, or disturbance of the beam; its sampling circle is a counting area, not a physical aperture, and a beam that only grazes it counts in full.